Yamaha CL5/CL3/CL1 V1.5 Manual do Utilizador Página 145

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 277
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 144
I/O device and external head amp
Reference Manual
145
Connecting the CL series console to an SB168-ES
To remotely control the SB168-ES from the CL series console, install an MY16-ES64 EtherSound card
in Slot 1 on the CL, then use an Ethernet cable to connect the CL to the SB168-ES. This connection
enables you to remotely control the SB168-ES from the CL series console.
Alternatively, you can use a daisy chain or ring connection and install two MY16-EX expansion cards
in the slots on the CL unit to remotely control up to three SB168-ES units simultaneously.
NOTE
Remote control data will be received and transmitted only at Slot 1 on the CL series console.
Daisy chain connection
Ring connection
NOTE
Please refer to the SB168-ES Owner’s Manual for information on setting up the MY16-ES64/
MY16-EX cards and EtherSound network.
SB168-ES
SB168-ES
SB168-ES
MY16-
ES64
MY16-
EX
MY16-
EX
CL5
OUT
Audio signal
Remote signal
IN
OUT
IN
IN
OUT
SB168-ES
SB168-ES
SB168-ES
CL5
MY16-
ES64
MY16-
EX
MY16-
EX
Audio signal
Remote signal
OUT
IN
OUT
IN
IN
OUT
OUT
Vista de página 144
1 2 ... 140 141 142 143 144 145 146 147 148 149 150 ... 276 277

Comentários a estes Manuais

Sem comentários