Vista de página 15
APPLICATION
Compact
single-axis robots
TRANSERVO
Single-axis robots
FLIP-X
Linear motor
single-axis robots
PHASER
Cartesian
robots
XY-X
SCARA
robots
YK-XG
Pick & place
robots
YP-X CLEAN
CONTROLLER
INFORMATION
396
Robot
positioner
Pulse string
driver
Robot
controller iVY
Option
Electric
gripper
Features
1 Main operation patterns
Normal operation Merge operation Output pattern
Moves to the target position relative
to the origin point and completes
positioning.
Moves from the current position
just by a distance specified in point
data and completes positioning.
Moves while pushing at a preset
push force.
Pushing starts after decelerating
at a distance equal to “Near width
(N)” from the target position.
P1 Position
Moves to a specified
coordinate position.
P1
Current position
Moves a specified distance
from the current position
P1
Pushes at a fixed thrust
P1
Decelerates and then
pushes
N
Speed
ABS (absolute) operation
Pushing operation
INC (incremental) operation
Pushing after decelerating
Moves to multiple points in
succession. If different speeds were
set, then the speeds are changed
without decelerating and stopping to
continue point-to-point operation.
P1 P2
Changes speed with no
deceleration
Merge operation
Zone for external I/O output can
be set for each point.
P1
Output turns ON when a
specified zone is entered
ON OFF
“Near width” output zone can be set for
each point as a position margin zone where
“positioning completesignal is to be output.
P1
Specify position margin
zone.
Zone output “Near widthoutput
2
Detailed data can be set for each point
Settings such as acceleration, deceleration, zone output
range, and position margin zone can be set for each point.
Different operations can be easily specied by combining
these settings with the above operation patterns.
Setting items
Setting item Description
1 Run type
Species operation pattern such as ABS, INC,
positioning, push, and point-to-point link.
2 Position Species position or distance to move.
3 Speed Species maximum speed during operation.
4 Accel. Species acceleration during operation.
5 Decel.
Species deceleration during operation
(Percentage of acceleration)
6 Push
Species motor current limitation during
pushing operation.
7 Zone (-)
Species upper and lower limits of “personal
zone” for each point data.
8 Zone (+)
9 Near width
Species position margin zone where “near
width” output should turn on.
10 Jump
Species next movement destination after positioning
or linked destination for point-to-point operation.
11 Flag Species stop mode and others.
12 Timer
Species the waiting time (delay) after
positioning completion.
Note:Acceleration and deceleration can be set in easy-to-understand percentage (%) units
(standard setup) or in SI units (custom setup) which make it easy to calculate the cycle time.
3 Maximum acceleration auto setting
Acceleration is a critical parameter that determines how
long the robot can continue operating (or service life).
In worst cases, setting the acceleration too high may
cause the robot to breakdown after a short time.
On the TS series, the maximum acceleration is finely set by
taking into account the service life span of the motor output and
the guide for each robot model and payload. This eliminates
any worry about setting the acceleration too high by mistake.
4
Full range of monitor functions
P. 411
The TS-Manager developed exclusively for the TS series
not only does data write, edit, backup tasks and parameter
settings but also comes loaded with cycle-time, simulator,
and monitor functions of all types.
A run-distance monitor for maintenance use is provided
as a standard unit feature. Design emphasizes easy,
user-friendly operation.
Main monitor displays
· Position
· Current
· Voltage
· Input information
· Output information
· Speed
· Load factor
· Temperature
5 LCD monitor showing easy-to-
understand operation status display
TS-X TS-P
A main-unit integrated type LCD monitor is available as
an optional unit. The operation status, current position,
load factor, and/or error contents can be understood at
a glance.
P. 405
6 Power supply voltage selectable
100V or 200V
TS-X TS-P
The power supply voltage for the TS-X and TX-P is
selectable from 100V or 200V.
Single axis
TS-S/TS-X/TS-P
TS series
TS series are positioner type controllers that only performs point trace. No program is needed.
Operation is simple. After setting point data, specify the point number and enter a START
signal from host controller such as a PLC. Positioning or pushing operation then begins.
CE compliance
TS-S
TS-X TS-P
Robot positioner
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 69 70

Comentários a estes Manuais

Sem comentários

Chief Manufacturing PNRIW manuali

Manuali dei proprietari e guide per l'utente per Accessori di montaggio per muro&soffitto Chief Manufacturing PNRIW.
We fornisce 1 manuali pdf Chief Manufacturing PNRIW per scaricare gratuitamente in base al tipo di documento: Manuale Utente






Più prodotti e manuali per Accessori di montaggio per muro&soffitto Chief Manufacturing

Modelli Tipo di Documento
CMA351 Manuale Utente    Chief Manufacturing CMA351 User's Manual, 8 pagine
MSA Series Manuale Utente   Chief Manufacturing MSA Series User's Manual, 12 pagine
PSB-2033 Manuale Utente   Chief Manufacturing PSB-2033 User's Manual [Néerlandais] , 4 pagine
MIWRF Series Manuale Utente   Chief Manufacturing MIWRF Series User's Manual, 12 pagine
KSA-1020 Manuale Utente   Chief Manufacturing KSA-1020 User's Manual, 12 pagine
CMA-347 Manuale Utente   Chief Manufacturing CMA-347 User's Manual, 8 pagine