ICD.CONTROL FUNCTIONS
SO SIMPLE AND SIMPLY PERFECT.
Standard manager
The standards library enables quick access to a list of standards tests.
In each standards list, the test modes are preprogrammed with substi-
tution or closed loop method. Custom tests can also be saved into the
standards list.
System behavior during DUT monitoring
When using Fail and and an external measuring device
Fail : > Stops and ends the test
Fail : > The following behavior options can be selected in case of
a Fail event:
> Entry in test graph and report
> Interruption of test with analysis option
> Full or semi-automatic disturbance threshold search
Disturbance threshold search
With this function, users can easily determine the disturbance
threshold. If the DUT is affected at a certain frequency, the software
automatically starts to search for the limit value and reports the
final level at which the DUT was unaffected by interference.
Control is manual or fully automatic.
Vector test routines
You can define and link all of the testing vectors yourself. You can
specify the start and end values of the vector (frequency and ampli-
tude), the modulation type, modulation depth, frequency intervals,
contact time, etc.
You can create special test frequencies in an Excel file.
icd.control uses these values for the test.
Set-up for calibration and testing
When you open opens a test routine, you can select previous calibra-
tion data (for BCI clamps and stripline) from the library or create your
own calibration file. icd.control displays both the calibration set-up
(image) and the test set-up (image ), so you don‘t have to spend
extra time searching in the respective standard.
Calibration procedure (e.g. per ISO -)
When the calibration routine is run, the required test level for each
frequency is noted and saved in the respective database. This ensures
that in the subsequent test, the entire frequency range can be tested
at a consistent level. This eliminates error because in the background,
the software monitors all of the operations.
ICD.CONTROL FUNCTIONS
ROUTINELY SUCCESSFUL
Measuring device connection
icd.control enables the connection of external measuring equipment
such as digital multi meters, oscilloscopes, spectrum analyzers,
and all types of measurement value recorders with interfaces. Many
measuring devices already exist in the library. The measuring devices
installed in the CWS N are also available in a dedicated field and
can be used for additional measurements.
Configuring an external measuring device
Here a simple method is used to configure all of the measuring
devices used for monitoring the DUT. In addition, trigger conditions,
measurement windows, measurement limit values as well as fail func-
tions and alarms can be activated and entered. icd.control support
GPIB, RS, USB and Ethernet interfaces.
Active test routines as per ISO -
Based on the clearly arranged measurement windows and graphics,
you can observe the test run at all times. The measured forward and
reflected power values as well as the injected current are displayed
in addition to the applied power and current values. Moreover, the
impedance behavior of the DUT is calculated from the measured
values and displayed as well. This delivers detailed information for
evaluating the behavior of the DUT.
Test routine as per ISO - Closed Loop
The closed loop process requires regulation of the output power. The
induced current is measured with a probe, compared with the desired
level and adjusted. This ensures that the correct level has been
tested.
Test routine with DUT monitoring
icd.control can control up to measuring devices at once for monito-
ring/checking the DUT. The respective measurement values are displa-
yed with the frequency information in a clearly arranged graphic.
ICD.CONTROL SOFTWARE
FOR CWS N
icd.control
Software
AUTOMOTIVE > EMC TEST SYSTEMS FOR AUTOMOTIVE ELECTRONICSAUTOMOTIVE > EMC TEST SYSTEMS FOR AUTOMOTIVE ELECTRONICS