Yamaha SRCP Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 24
5
Parameters
5-1
Chapter 5 Parameters
5-1 Parameter setting
For information on how to set parameters with the TPB, refer to "5-1 Setting parameters"
in the SRCP controller user's manual. A TPB version of V12.50 or higher is required.
5-2 Parameter list
Some parameters become effective by turning the power off and then on again. After
changing those parameters be sure to turn the power off once and then back on again.
The shaded PRM (parameter) numbers are hidden parameters and usually cannot be
displayed on the TPB. See "10-5-1 Viewing hidden parameters" in the SRCP controller
user's manual for information on how to write and display these parameters.
The alphabet letters in the "Relevant control mode" column mean as follows: S is normal
mode and P is pulse train mode.
The alphabet letter "R" in the "Setting range" column signifies a read-only parameter.
The asterisk (*) indicates the value differs according to the robot.
PRM1 (Common parameters)
PRM
No.
Parameter name Setting range
Default value
Unit
Relevant control mode,
etc.
Power
off and on
Robot type number
(+) Soft limit
(–) Soft limit
Payload
Acceleration
Return-to-origin direction
Positioning completed pulse
I/O point movement command speed
No. of conditional input points
MOVF speed
Return-to-origin speed
No. of encoder pulses (after multiplied 4)
Lead length
Origin detection method
Overload current
Overload time
Current limit
Speed proportional gain (Kvp)
Speed integration gain (Kvi)
Position proportional gain (Kpp)
OUT valid position
Position data unit
English/Japanese selection
Payload-dependent acceleration coefficient
Teaching count data
(Not used)
Teaching movement data
Teaching movement data 1
Teaching movement data 2
Teaching movement data 3
Maximum program speed
Mechanical lock detection level
R
-9999 to 9999
-9999 to 9999
*
1 to 200
0 or 1
1 to 4000
0 to 100
1 to 8
1 to *
1 to 100
0 to 1
1 to 10000
1 to 10000
1 to 40959
300 to 90000
200 to 60000
1 to 1000
0 to 9999
0 to 3
0 to 1
1 to 255
1 to 100
1 to 100
1 to 100
1 to 100
0 to 255
*
*
*
0
100
*
80
100
4
10
20
*
*
1
*
*
*
*
*
*
1
0
0
*
0
100
100
50
10
100
255
mm
mm
Kg
%
Pulse
%
Point
mm/s
mm/s
Pulse
.01mm
mm
%
%
%
%
%
%
.01s
Common
S
S
S
S
Common
Common
S
S
S
Common
Common
Common
Common
Common
Common
Common
Common
Common
Common
S
S
Common
S
S
S
S
S
S
S
Common
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Vista de página 24